G2A07N09GMA
3/4" NPT Female Aluminum (see new model)
Search for model G2A07NQ9GMA
Rate & Totals G2 Series - INDUSTRIAL GRADE METER
Main Specifications
Connection Size: 3/4"
Connection Type: NPT Female
Flow Range: 2 - 20 GPM (7.6 - 75.7 LPM)
See new model
G2A07NQ9GMA
See new model
G2A07NQ9GMA
Pressure Rating: 300 PSI (21 Bar)
Operating Temp With Local Computer: 14°F to 140°F (-10°C to 60°C)
Meter Body Size: 3/4"
Local/Remote Display: None
Display Type: None
Factory Calibrated For: Water like fluids
Flow Meter Type: G2 Series - INDUSTRIAL GRADE METER
Std Calibration Reports Included: Yes
Warranty Period: 1 Year
Product Type: Rate & Totals
Benefits & Features: Accurate; Durable; 5-Year Battery Powered; 6 Digit Display - Floating Decimal; Rate of Flow; Batch & Cumulative Totals; Factory Calibrated and Field Calibratable; Add-On Output Options; FM Approved Class I, Div. I; Replaceable Internal Meter Body Parts; Choice of Gallons or Liters; Custom Programmable Display (including UOM)
Extended Flow Range: 20 - 30 GPM (75.7 - 113.6 LPM)*
Max Pressure Drop (at Max Flow in test conditions): 5.2 PSI
Accuracy (% of Reading) Factory Calibrated with Computer: ± 1.0%
Accuracy (% of Reading) Factory Calibrated Body Only: ± 1.5%
Repeatability (based on test conditions): ± 0.1%
Maximum Viscosity: 100 cps**
Recommended Strainer Size: 120 Mesh (125 Microns)
Max. Particle Size: .005" / .127 mm
Operating Temp Without Local Computer or With Remote Computer: -40 to 250°F (-40 to 121°C) [Opt'l]
Housing Material: Aluminum (see new model) <br><br>Search for model G2A07NQ9GMA
Bearings: 96% Alumina Ceramic/Tungsten Carbide
Shaft: Tungsten Carbide
Rotor: PVDF
Signal Generator: Not Wetted
Retaining Rings: 316SS
Local Computer Calibrations: Factory
Typical K-Factor PPG (PPL): 1100 (291)
Local Module & Output Signal: 4-20mA Transmitter
Remote Output: None
Sensor (Pickup): Magnetic
External Power: 2-Wire Loop Powered 8.5-35 VDC
Frequency Range: 37 - 370 Hz
Applications (always check Chemical Compatibility Guide): Fuel, Diesel, Petroleum Based Products
Not Suitable For Applications: Water; Oils, especially those heavier than 10W (100cps), Fluctuating viscosities**
Application Notes: Unidirectional but Display can be rotated 180°, Can mount Horizontally or Vertically, Can use for Gravity Feeds
Minimum Straight Pipe Dia.s: 7.5" Upstream / 3.75" Downstream
Desired Straight Pipe Dia.s: 14" Upstream / 7.5" Downstream
Connection to Connection Length (OAL): 4.3" (109 mm)
Shipping Weight (Approximate): 1.4 lbs (0.63 kg)
Approvals Notes: See catalog page for full approval specs