The Largest IN-STOCK FLOW METER Warehouse + Ships Same Day!

Authorized Distributor of FLOMEC & GPI Flow Meters

G2H07N09GMA

3/4" NPT Female 316SS (see new model)

Search for model G2H07NQ9GMA

Rate & Totals G2 Series - INDUSTRIAL GRADE METER - HIGH PRESSURE

No longer available.

See New/Alternate Model No: View
Main Specifications
Connection Size: 3/4"
Connection Type: NPT Female
Pressure Rating: 3000 PSI (207 Bar)
Operating Temp With Local Computer: 14°F to 140°F (-10°C to 60°C)
Flow Range: 2 - 20 GPM (7.6 - 75.7 LPM)

See new model
G2H07NQ9GMV
Meter Body Size: 3/4"
Body Type: High Pressure
Local/Remote Display: Local
Display Type: Digital LCD
Factory Calibrated For: Water like fluids
Flow Meter Type: G2 Series - INDUSTRIAL GRADE METER - HIGH PRESSURE
Std Calibration Reports Included: Yes
Warranty Period: 1 Year
Product Type: Rate & Totals
Benefits & Features: High Pressure Rated (3000 PSI); Excellent Chemical Compatibility; Accurate; Durable; 5-Year Battery Powered; 6 Digit Display - Floating Decimal; Rate of Flow; Batch & Cumulative Totals; Factory Calibrated and Field Calibratable; Add-On Output Options; FM Approved Class I, Div. I; Replaceable Internal Meter Body Parts; Choice of Gallons or Liters; Custom Programmable Display (including UOM)
Extended Flow Range: 20 - 30 GPM (75.7 - 113.6 LPM)*
Max Pressure Drop (at Max Flow in test conditions): 5.2 PSI
Accuracy (% of Reading) Factory Calibrated with Computer: ± 1.0%
Accuracy (% of Reading) Factory Calibrated Body Only: ± 1.5%
Repeatability (based on test conditions): ± 0.1%
Maximum Viscosity: 100 cps**
Recommended Strainer Size: 120 Mesh (125 Microns)
Max. Particle Size: .005" / .127 mm
Operating Temp Without Local Computer or With Remote Computer: -40 to 250°F (-40 to 121°C) [Opt'l]
Housing Material: 316SS (see new model) <br><br>Search for model G2H07NQ9GMA
Bearings: 96% Alumina Ceramic/Tungsten Carbide
Shaft: Tungsten Carbide
Rotor: PVDF
Signal Generator: Not Wetted
Retaining Rings: 316SS
Display Function: Rate + 2 Totals (1 Resettable, 1 Cumulative)
Local Computer Calibrations: Factory & Field
LCD Digits: 6
Totalizing Display Starting Increment: 0.01
Typical K-Factor PPG (PPL): 565 (149)
Local Module & Output Signal: None
Remote Output: Optional Remote Display, 4-20mA or Pulse Out (Please contact us)
Sensor (Pickup): Magnetic
Battery Power: (2) 3V Lithium Battery (5 year)
Frequency Range: 47 - 470 Hz
Totalizing Resets to 0 After Reaching: 99999999
Applications (always check Chemical Compatibility Guide): High Press Water Spray Washers and Hydraulic Systems, Chemicals, Fuel Products
Not Suitable For Applications: DI Water; Oils, especially those heavier than 10W (100cps), Fluctuating viscosities**
Application Notes: Unidirectional but Display can be rotated 180°, Can mount Horizontally or Vertically, Can use for Gravity Feeds
Minimum Straight Pipe Dia.s: 7.5" Upstream / 3.75" Downstream
Desired Straight Pipe Dia.s: 14" Upstream / 7.5" Downstream
Connection to Connection Length (OAL): 4.3" (109 mm)
Shipping Weight (Approximate): 2.4 lbs (1.1 kg)
Approvals Notes: CE Approvals Only; See catalog page for full approval specs